Mobile Hygiene Station
The electrical requirements and connections are:
UK: 13amp, 240V – The unit is fitted with a three core 1.5mm² conductor for the 3.0kW unit Enclosure fitted with an RCD 25amp – 30mA, 16amp MCB for the I3V Hand wash and a 2amp inline fuse for the PIR light protection.
Plumbing
The unit requires a 3/8″ plastic pipe connected to the Hand wash from the outlet side of the foot pump.
I3V Handwash Specification
Heat Loading: 3kW
Fuse Rating: 13amp
Recommended Cable size: 1.5mm
Water Pressure: Min 10 psi (0.7 BAR) Max 100 psi
(7 BAR)
Flow Control : A flow control knob which can be adjusted between winter and summer to take account of the temperature of the incoming water.
Safety: Stabilised flow control
Water pressure operated power switch over temperature thermal cutout
Materials:
Backplate and Cover: High gloss/high strength ABS plastic
Element: High grade copper sheathed
Spray arm: Stainless Steel
Vortex spray head: ABS plastic